-
1 × $521.00
-
1 × $1,406.00
-
1 × $997.00
-
2 × $1,718.00
-
1 × $8,869.00
-
1 × $2,533.00
-
1 × $471.00
-
1 × $537.00
-
1 × $2,527.00
-
2 × $388.00
-
1 × $5,122.00
-
1 × $704.00
-
1 × $422.00
-
1 × $621.00
-
1 × $1,034.00
-
1 × $1,125.00
-
1 × $3,723.00
-
1 × $1,198.00
-
1 × $951.00
-
3 × $656.00
-
2 × $554.00
-
1 × $608.00
-
1 × $1,345.00
-
1 × $1,194.00
-
1 × $2,223.00
-
4 × $373.00
-
1 × $784.00
-
1 × $983.00
-
1 × $1,389.00
-
1 × $2,724.00
-
1 × $3,416.00
-
2 × $477.00
-
1 × $693.00
-
1 × $2,190.00
-
1 × $7,433.00
-
2 × $570.00
-
2 × $682.00
-
1 × $1,185.00
-
1 × $1,585.00
-
1 × $897.00
-
3 × $2,776.00
-
1 × $3,931.00
-
1 × $5,036.00
-
1 × $2,133.00
-
1 × $442.00
-
1 × $1,321.00
-
1 × $6,281.00
-
1 × $7,451.00
-
1 × $425.00
-
1 × $573.00
-
2 × $607.00
-
1 × $1,720.00
-
2 × $468.00
-
1 × $3,544.00
-
1 × $858.00
-
1 × $12,596.00
-
1 × $4,667.00
-
1 × $2,436.00
-
1 × $1,819.00
-
2 × $3,411.00
-
1 × $401.00
-
1 × $2,361.00
-
1 × $560.00
-
1 × $2,492.00
-
2 × $855.00
-
1 × $25,527.00
-
1 × $471.00
-
1 × $416.00
-
1 × $1,369.00
-
1 × $616.00
-
1 × $1,548.00
-
1 × $403.00
-
1 × $3,417.00
-
2 × $1,511.00
-
1 × $2,361.00
-
1 × $2,520.00
-
1 × $1,092.00
-
1 × $2,168.00
-
1 × $788.00
-
2 × $2,435.00
-
1 × $471.00
-
1 × $521.00
-
1 × $6,456.00
-
1 × $754.00
-
1 × $444.00
-
2 × $832.00
-
1 × $1,206.00
-
1 × $3,051.00
-
1 × $1,640.00
-
2 × $521.00
-
1 × $492.00
-
1 × $740.00
-
1 × $642.00
-
1 × $5,458.00
-
1 × $2,184.00
-
1 × $1,337.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information
- 1-Year Warranty