1 × $642.00
-
1 × $442.00
-
1 × $1,843.00
-
1 × $1,177.00
-
1 × $3,778.00
-
2 × $1,848.00
-
1 × $1,577.00
-
1 × $596.00
-
2 × $1,345.00
-
1 × $1,862.00
-
1 × $2,168.00
-
1 × $745.00
-
1 × $1,755.00
-
1 × $2,390.00
-
1 × $1,363.00
-
1 × $573.00
-
1 × $4,355.00
-
3 × $603.00
-
1 × $403.00
-
1 × $471.00
-
2 × $3,237.00
-
1 × $2,184.00
-
1 × $450.00
-
1 × $1,467.00
-
1 × $5,861.00
-
1 × $2,520.00
-
1 × $454.00
-
1 × $395.00
-
1 × $1,575.00
-
2 × $401.00
-
2 × $1,389.00
-
1 × $1,555.00
-
2 × $399.00
-
2 × $2,435.00
-
1 × $897.00
-
1 × $471.00
-
1 × $1,130.00
-
3 × $6,360.00
-
1 × $569.00
-
2 × $2,133.00
-
1 × $2,314.00
-
1 × $616.00
-
1 × $404.00
-
1 × $1,091.00
-
1 × $832.00
-
1 × $579.00
-
1 × $816.00
-
1 × $3,604.00
-
1 × $1,257.00
-
1 × $471.00
-
1 × $607.00
-
1 × $1,068.00
-
1 × $2,724.00
-
2 × $573.00
-
1 × $1,642.00
-
1 × $788.00
-
1 × $1,293.00
-
1 × $467.00
-
2 × $1,278.00
-
1 × $1,511.00
-
1 × $554.00
-
1 × $416.00
-
1 × $1,819.00
-
1 × $5,582.00
-
1 × $740.00
-
1 × $7,392.00
-
1 × $1,106.00
-
1 × $2,184.00
-
1 × $2,218.00
-
1 × $457.00
-
1 × $2,492.00
-
1 × $2,184.00
-
1 × $1,826.00
-
1 × $3,945.00
-
1 × $1,271.00
-
1 × $2,533.00
-
1 × $385.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information
- 1-Year Warranty