3 × $398.00
-
2 × $2,314.00
-
1 × $1,340.00
-
2 × $1,718.00
-
3 × $579.00
-
1 × $1,406.00
-
1 × $1,113.00
-
1 × $784.00
-
1 × $1,337.00
-
1 × $876.00
-
1 × $16,982.00
-
1 × $4,968.00
-
1 × $8,707.00
-
1 × $951.00
-
1 × $554.00
-
1 × $2,790.00
-
1 × $2,533.00
-
1 × $1,418.00
-
1 × $521.00
-
2 × $7,392.00
-
3 × $698.00
-
1 × $858.00
-
1 × $816.00
-
2 × $760.00
-
1 × $896.00
-
1 × $467.00
-
1 × $467.00
-
2 × $915.00
-
1 × $1,510.00
-
1 × $471.00
-
1 × $575.00
-
1 × $2,738.00
-
1 × $555.00
-
2 × $2,390.00
-
1 × $1,511.00
-
1 × $404.00
-
1 × $2,435.00
-
1 × $5,036.00
-
1 × $569.00
-
2 × $395.00
-
2 × $670.00
-
2 × $712.00
-
1 × $2,057.00
-
1 × $3,778.00
-
1 × $887.00
-
1 × $1,191.00
-
1 × $1,257.00
-
1 × $2,361.00
-
1 × $537.00
-
1 × $820.00
-
1 × $2,184.00
-
1 × $673.00
-
1 × $1,073.00
-
2 × $1,585.00
-
1 × $642.00
-
1 × $2,050.00
-
2 × $521.00
-
1 × $3,544.00
-
1 × $1,257.00
-
1 × $1,990.00
-
1 × $2,184.00
-
2 × $1,029.00
-
2 × $2,782.00
-
2 × $524.00
-
2 × $3,385.00
-
1 × $471.00
-
1 × $2,492.00
-
1 × $1,256.00
-
1 × $713.00
-
1 × $897.00
-
2 × $745.00
-
1 × $2,168.00
-
1 × $1,642.00
-
1 × $2,219.00
-
1 × $569.00
-
1 × $2,223.00
-
2 × $608.00
-
1 × $1,467.00
-
2 × $547.00
-
1 × $6,360.00
-
1 × $628.00
-
1 × $425.00
-
1 × $573.00
-
2 × $3,417.00
-
1 × $415.00
-
1 × $1,237.00
-
2 × $1,255.00
-
2 × $521.00
-
1 × $3,237.00
-
1 × $1,041.00
-
1 × $391.00
-
1 × $616.00
-
1 × $3,834.00
-
1 × $855.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information