1 × $1,237.00
-
1 × $2,527.00
-
1 × $492.00
-
2 × $760.00
-
2 × $3,411.00
-
1 × $401.00
-
1 × $1,095.00
-
1 × $2,042.00
-
1 × $484.00
-
1 × $713.00
-
1 × $2,756.00
-
2 × $530.00
-
1 × $10,545.00
-
1 × $454.00
-
1 × $1,421.00
-
1 × $3,286.00
-
1 × $997.00
-
1 × $437.00
-
1 × $2,190.00
-
1 × $1,087.00
-
2 × $1,970.00
-
3 × $1,467.00
-
1 × $1,896.00
-
2 × $2,724.00
-
1 × $5,458.00
-
2 × $4,645.00
-
1 × $2,805.00
-
1 × $1,068.00
-
3 × $2,492.00
-
1 × $471.00
-
2 × $1,281.00
-
1 × $1,086.00
-
1 × $3,077.00
-
2 × $915.00
-
1 × $4,184.00
-
2 × $616.00
-
1 × $1,309.00
-
1 × $395.00
-
1 × $521.00
-
1 × $1,527.00
-
1 × $2,533.00
-
1 × $2,465.00
-
1 × $6,930.00
-
1 × $613.00
-
3 × $2,782.00
-
1 × $1,843.00
-
2 × $5,226.00
-
2 × $740.00
-
2 × $471.00
-
1 × $20,652.00
-
1 × $1,725.00
-
1 × $2,361.00
-
2 × $657.00
-
1 × $951.00
-
1 × $1,819.00
-
1 × $3,778.00
-
1 × $399.00
-
1 × $6,360.00
-
1 × $2,790.00
-
1 × $1,687.00
-
1 × $2,361.00
-
1 × $1,863.00
-
2 × $656.00
-
3 × $706.00
-
1 × $1,117.00
-
2 × $608.00
-
5 × $852.00
-
1 × $2,190.00
-
1 × $1,369.00
-
1 × $560.00
-
1 × $1,031.00
-
1 × $642.00
-
1 × $3,286.00
-
1 × $446.00
-
2 × $442.00
-
1 × $894.00
-
1 × $897.00
-
1 × $607.00
-
1 × $3,237.00
-
1 × $673.00
-
2 × $1,642.00
-
1 × $561.00
-
1 × $670.00
-
1 × $1,091.00
-
1 × $1,185.00
-
1 × $2,218.00
-
1 × $2,520.00
-
1 × $4,052.00
-
2 × $2,184.00
-
1 × $819.00
-
1 × $1,440.00
-
1 × $4,355.00
-
1 × $394.00
-
1 × $954.00
-
1 × $1,111.00
-
1 × $373.00
-
1 × $2,050.00
-
1 × $521.00
-
1 × $1,191.00
-
1 × $573.00
-
1 × $1,718.00
-
1 × $1,198.00
-
1 × $2,776.00
-
1 × $784.00
-
1 × $682.00
-
1 × $477.00
-
1 × $1,293.00
-
1 × $2,164.00
-
1 × $575.00
-
1 × $25,527.00
-
1 × $2,141.00
-
1 × $956.00
-
1 × $1,643.00
-
1 × $897.00
-
1 × $3,067.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information
- 1-Year Warranty