The Microcap Plus has Microstream® capnography and Nellcor pulse oximetry in one convenient portable device providing accurate, continuous monitoring on intubated and non-intubated patients from neonate to adult in hospital and pre-hospital environments, including emergency transport.
Features and Benefits
- Provides capnography.
- Portable light-weight monitor including both capnography and pulse oximetry.
- CO2 specific emission source eliminates need to calibrate for presence of other gases.
- Accurate and reliable in the presence of various gases and a wide range of temperature environments.
- No need for manual calibration and zeroing, water traps, or flushing monitor between patients.
- Flow rate of only 50 ml/min, especially suitable for neonatal sampling. Utilizes small sample cell (15 µl) for quick responsiveness and accurate monitoring, even with high respiratory rates.
- Interfaces to Bernoulli MSM, Oxinet, Philips (via VueLink) and Spacelabs (via Flexport) monitoring systems, nurse call systems.
- Approved for use in emergency transport.
Technical Specifications
Capnography
- Display Range: 0-99 mmHg.
- 0-13.0 Vol %
- 0-13.2 kPa.
- CO2 sampling flow rate 50 ml/ min.
- Warm-up time 30 seconds typical.
- Accuracy 0-38 mmHg ± 2 mmHg.
- 39-99 mmHg ± 5% of reading.
- Respiration rate 0-150 breaths/min.
- Modes Adult, neonatal.
- Alarms Adjustable alarm limits for EtCO2, FiCO2, and Respiration Rate.
- Display Graphic LCD display (128 x 64 dots) with LED backlight (contrast and backlight control), Bright, seven-segment LED for numeric display of EtCO2 and respiration rate, Two color alarm bar.
- Nurse Call and Bernoulli MSM RS232 interface between monitor and remote systems. Nurse Call System can be easily wired via stereo phone jack.
- Interface Compatibility: Microcap® only – one parameter (v3.15 and higher): Output to Philips CMS 2001, V24, V26 via VueLink A01 and A05. Output to Spacelabs Ultraview®, PCMS™ , PCIS™, UCW®, and PC Scout® via Flexport 0152 and 0555.
Pulse Oximetry
- Display Range: SpO2 Saturation 0%-100%
- Pulse Rate 20-250 beats/minutes.
- Accuracy: Adults 70%-100% ± 2 digits, 0-69% unspecified.
- Neonate 70%-100% ± 2 digits, 0-69% unspecified.