-
1 × $2,402.00
-
2 × $25,527.00
-
1 × $1,418.00
-
1 × $897.00
-
2 × $2,218.00
-
3 × $437.00
-
2 × $494.00
-
1 × $1,746.00
-
1 × $2,190.00
-
1 × $492.00
-
1 × $469.00
-
1 × $1,322.00
-
1 × $554.00
-
2 × $706.00
-
1 × $520.00
-
2 × $435.00
-
2 × $2,776.00
-
1 × $6,759.00
-
1 × $1,970.00
-
2 × $2,361.00
-
2 × $942.00
-
1 × $951.00
-
1 × $2,152.00
-
3 × $613.00
-
1 × $1,194.00
-
1 × $521.00
-
1 × $887.00
-
1 × $479.00
-
1 × $1,393.00
-
3 × $2,079.00
-
1 × $1,394.00
-
1 × $628.00
-
2 × $2,724.00
-
1 × $1,010.00
-
1 × $2,361.00
-
1 × $1,309.00
-
2 × $1,643.00
-
1 × $1,725.00
-
1 × $839.00
-
1 × $2,219.00
-
1 × $1,092.00
-
1 × $524.00
-
1 × $1,337.00
-
1 × $1,793.00
-
1 × $1,640.00
-
1 × $454.00
-
1 × $538.00
-
1 × $7,433.00
-
1 × $2,163.00
-
1 × $470.00
-
1 × $709.00
-
1 × $1,281.00
-
1 × $471.00
-
1 × $1,421.00
-
1 × $1,068.00
-
1 × $855.00
-
2 × $788.00
-
1 × $1,018.00
-
1 × $1,068.00
-
1 × $2,810.00
-
1 × $896.00
-
1 × $1,887.00
-
1 × $2,957.00
-
1 × $2,361.00
Erler Zimmer 12-lead Arrhythmia Simulator (Heart Start/Philips With Late VF Waveform)
$1,511.00
Erler zimmer 12-lead arrhythmia simulator (heart start/philips with late vf waveform)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty