3 × $2,039.00
-
1 × $444.00
-
1 × $3,416.00
-
1 × $1,540.00
-
1 × $3,945.00
-
1 × $701.00
-
2 × $1,345.00
-
1 × $24,377.00
-
1 × $607.00
-
1 × $401.00
-
1 × $2,050.00
-
1 × $2,184.00
-
2 × $1,585.00
-
1 × $2,314.00
-
1 × $1,282.00
-
1 × $2,050.00
-
1 × $1,566.00
-
1 × $1,440.00
-
1 × $816.00
-
1 × $1,098.00
-
1 × $7,839.00
-
2 × $4,379.00
-
1 × $1,755.00
-
1 × $446.00
-
2 × $1,720.00
-
1 × $569.00
-
1 × $855.00
-
1 × $2,900.00
-
1 × $401.00
-
3 × $1,394.00
-
2 × $399.00
-
1 × $1,257.00
-
2 × $2,009.00
-
1 × $1,122.00
-
1 × $24,377.00
-
1 × $2,190.00
-
1 × $1,106.00
-
1 × $25,527.00
-
1 × $1,019.00
-
2 × $477.00
-
1 × $3,012.00
-
1 × $4,437.00
-
1 × $539.00
-
1 × $2,223.00
-
1 × $1,003.00
-
2 × $670.00
-
2 × $1,534.00
-
1 × $1,164.00
-
1 × $438.00
-
1 × $2,188.00
-
1 × $1,706.00
-
1 × $1,389.00
The DR400 Patch is the smallest and most versatile monitor in the line-up of cardiac monitors from Northeast Monitoring. Weighing in at less than 30 grams, the shower-proof 1-, 2- or 3-lead “Patch” style recorder solves your remote cardiac monitoring needs. With 14-day Holter, 30-day Event and Mobile Cardiac Telemetry (MCT) capabilities, this multi-functional recorder uses Bluetooth technology to transmit cardiac events every 20 minutes making ECG transmissions near-real-time.
Features and Benefits
- Up to 14-day Holter
- 30-day wireless Event monitoring
- 1-, 2-, or 3 channel recording
- 1, 2- or 3-electrode patch
- Powered by an internal lithium battery
- Micro USB connectivity
Materials Included
- DR 400 Recorder
- (1) Recorder Patch
- (1) Single Lead Wire
- (1) Power Cable Adapter
- User Manual
*Note: The HE/LX V6.0 Analysis Software is required.
Technical Specifications
- Performance Specifications
- Sampling Rate: 180 samples/second
- Resolution: 12-bit, 12.50 V/LSB
- Recording Bandwidth: 0.05- 70 Hz
- Water Resistance: IP55 (prelim)
- Physical Specification
- Dimensions: 2.3′ x 1.6′ x 0.4′
- Weight: 30 grams (1.0 oz) with battery
- Electrical Specifications
- Recording Bandwidth: 0.05 to 70 hertz in 180 samples/sec. mode
- Operation Duty Cycle: Continuous.
- Data Storage Format: Sample difference.
- Pacemaker Sensitivity: 2 millivolts.
- Pacemaker Pulse Duration: 150 to 2,500 microseconds.
- Environmental Specifications
- The operating range of the device is between 10 and 45 degrees C, between 10 and 95% humidity, and between 700 and 1060 hPa pressure.
- Store and/or transport the recorder at temperatures between -40 and 70 degrees C, between 10 and 100% relative humidity, and 500 and 1060 hPa pressure
- Battery Specifications
- Internal lithium, USB charge, 1 charge for 14-day Holter or 30-day Event
Warranty Information
- 3-Year Warranty
Documentation
Brochure