-
1 × $2,428.00
-
1 × $472.00
-
1 × $3,998.00
-
1 × $1,250.00
-
1 × $873.00
-
1 × $1,091.00
-
1 × $6,406.00
-
1 × $2,810.00
-
1 × $2,435.00
-
1 × $406.00
-
1 × $978.00
-
1 × $594.00
-
1 × $396.00
-
1 × $2,133.00
-
1 × $1,337.00
-
1 × $560.00
-
1 × $1,237.00
-
1 × $520.00
-
1 × $1,891.00
-
1 × $682.00
-
1 × $481.00
-
1 × $2,502.00
-
1 × $852.00
-
1 × $2,164.00
-
1 × $820.00
-
1 × $2,236.00
-
1 × $1,467.00
-
2 × $1,793.00
-
1 × $392.00
-
1 × $585.00
-
1 × $784.00
-
1 × $1,848.00
-
1 × $7,996.00
-
1 × $6,848.00
-
1 × $2,361.00
-
1 × $4,007.00
-
1 × $26,171.00
-
1 × $393.00
-
1 × $575.00
-
1 × $1,092.00
-
1 × $1,389.00
-
1 × $818.00
-
1 × $554.00
-
1 × $1,034.00
-
1 × $1,224.00
-
1 × $416.00
-
1 × $3,152.00
-
1 × $467.00
-
1 × $4,461.00
-
1 × $1,610.00
-
1 × $521.00
-
1 × $1,098.00
-
1 × $3,897.00
-
2 × $2,142.00
-
1 × $9,860.00
-
1 × $2,206.00
-
1 × $1,204.00
-
1 × $399.00
-
1 × $745.00
-
1 × $1,951.00
-
1 × $1,169.04
-
1 × $25,527.00
-
1 × $2,297.00
-
1 × $2,629.00
-
1 × $399.00
-
1 × $5,505.00
-
1 × $554.00
-
1 × $764.00
-
1 × $7,392.00
-
1 × $2,602.00
-
1 × $1,247.00
-
1 × $643.00
-
1 × $1,752.00
-
1 × $1,428.00
-
1 × $740.00
-
1 × $435.00
-
1 × $522.00
-
1 × $870.00
-
1 × $504.00
-
1 × $26,445.00
-
1 × $1,040.00
-
1 × $457.00
-
1 × $896.00
-
1 × $411.00
-
1 × $530.00
-
1 × $1,272.00
-
1 × $437.00
-
1 × $547.00
-
1 × $20,652.00
-
1 × $1,223.00
-
1 × $2,393.00
-
1 × $616.00
-
1 × $435.00
-
1 × $7,663.00
-
1 × $7,735.00
-
1 × $2,496.00
-
1 × $887.00
-
1 × $5,451.00
-
1 × $1,421.00
-
1 × $1,097.00
-
1 × $3,780.00
-
1 × $1,128.00
-
1 × $701.00
-
1 × $1,029.00

Roll over image to zoom in
ART phantoms are molded of tissue-equivalent material, they are designed within highly sophisticated technological constraints and follow ICRU-44 standards. They are also designed for accuracy and ease of use.
Features and Benefits
- Anatomy
- The ART phantom is transected-horizontally into 2.5 cm thick slices.
- Each slice has holes which are plugged with bone-equivalent, soft-tissue-equivalent or lung tissue equivalent pins which can be replaced by TLD holder pins.
- Soft-tissue-equivalent coatings produce slices with glass smooth interfaces.
- These coatings are cut away over the air spaces of the oronasal pharynges, trachea and stem bronchi.
- Dosimetry holes are drilled in grids 3cm x 3cm or 1.5cm x 1.5cm in 5 and 7 mm diameters.
- The Male ART Phantom represents a 175 cm (5 ft. 9 in.) tall, 73.5 kg (162 lb.) male.
- Breast Attachments
- They can be sliced in frontal planes (drilled or undrilled for film dosimetry).
- Breasts of Male and Female ART phantoms are contoured to blend realistically with the thoraxes.
- They are attached to the thorax with nylon screws.
- The male chest with breasts attached serves as a large female.
- Materials
- Soft Tissues
- There are unlimited, small variations in density and absorption throughout the human body.
- Phantom soft tissue is closely controlled to have the average density of these tissues.
- Skeletons
- RSD skeletons are highly-detailed polymer moldings which reproduce the shape, mass density and attenuation coefficients of cortical bone and spongiosa.
- They allow continuous production of phantoms, instead of the sporadic production required by the limited availability, variable size and uncertain chemical composition of human skeletons.
- These problems, plus loss of marrows in dried natural skeletons, make RSD skeletons superior to “real bone”.
- Molds for the RSD cortical bone and spongiosa were made from human skeletons consistent with the sizes of the soft tissue molds.
- RSD skeletons conform closely to the standards established by the International Commission on Radiation Units and Measurements (ICRU Report No. 44), mass density is reduced slightly to take into account a small decrease in calcium content for older patients.
- Lungs
- Lungs are molded from syntactic foam, with a specific gravity of 0.30 g/cc.
- Soft Tissues
- Assembly
- ART phantom slices are held between aluminum plates by nylon tie rods.
- Knobs at the end of the rods clamp the slices tightly in proper alignment.
- The external assembly facilitates film dosimetry, while the internal assembly is used generally with TLDs or ionchamber dosimetry.
Warranty Information
- 5-Year Warranty