16 × $673.00
-
19 × $415.00
-
3 × $4,374.00
-
20 × $391.00
-
31 × $3,604.00
-
4 × $1,237.00
-
28 × $525.00
-
5 × $467.00
-
8 × $813.00
-
31 × $3,486.00
-
28 × $1,111.00
-
23 × $398.00
-
18 × $1,191.00
-
13 × $1,255.00
-
17 × $3,931.00
-
2 × $1,125.00
-
2 × $1,717.00
-
3 × $4,072.00
-
25 × $1,052.00
-
26 × $858.00
-
2 × $521.00
-
3 × $819.00
-
10 × $1,191.00
-
5 × $1,718.00
-
3 × $403.00
-
2 × $788.00
-
23 × $698.00
-
21 × $477.00
-
17 × $538.00
-
22 × $1,725.00
-
4 × $573.00
-
18 × $784.00
-
6 × $830.00
-
9 × $819.00
-
1 × $2,832.00
-
28 × $1,575.00
-
1 × $1,058.00
-
1 × $6,360.00
-
2 × $569.00
-
4 × $581.00
-
2 × $520.00
-
3 × $1,309.00
-
3 × $863.00
-
1 × $385.00
-
3 × $1,091.00
-
3 × $670.00
-
5 × $521.00
-
1 × $1,973.00
-
1 × $618.00
-
1 × $24,377.00
-
1 × $845.00
-
3 × $2,165.00
-
6 × $521.00
-
4 × $395.00
-
9 × $2,452.00
-
1 × $2,531.00
-
2 × $816.00
-
6 × $561.00
-
5 × $4,072.00
-
3 × $1,440.00
-
1 × $413.00
-
2 × $399.00
-
2 × $652.00
-
2 × $1,389.00
-
2 × $10,107.00
-
5 × $2,314.00
-
2 × $547.00
-
1 × $5,458.00
-
3 × $573.00
-
2 × $403.00
-
1 × $1,717.00
-
3 × $472.00
-
1 × $3,385.00
-
4 × $403.00
-
7 × $579.00
-
1 × $812.00
-
1 × $4,072.00
-
1 × $1,257.00
-
1 × $492.00
-
1 × $3,872.00
-
2 × $897.00
-
1 × $1,341.00
-
2 × $399.00
-
1 × $897.00
-
2 × $442.00
-
1 × $5,086.00
-
2 × $680.00
-
1 × $13,010.00
-
1 × $2,164.00
-
1 × $849.00
-
1 × $820.00
-
1 × $530.00
-
1 × $5,226.00
-
1 × $1,793.00
-
1 × $1,467.00
-
1 × $2,361.00
-
3 × $537.00
-
1 × $447.00
-
1 × $3,220.00
-
1 × $1,824.00
-
1 × $2,533.00
-
1 × $2,390.00
-
2 × $4,355.00
-
1 × $635.00
-
1 × $1,638.00
-
1 × $1,092.00
-
1 × $582.00
-
1 × $1,843.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty