-
1 × $706.00
-
2 × $858.00
-
2 × $682.00
-
2 × $616.00
-
1 × $712.00
-
1 × $1,224.00
-
1 × $1,585.00
-
1 × $607.00
-
6702SP Oversized Wheelchair Scales with standard weight (lb/kg) (X), data port (X) and battery power1 × $2,771.00
-
1 × $941.00
-
1 × $430.00
-
2 × $1,111.00
-
1 × $538.00
-
2 × $2,436.00
-
3 × $573.00
-
1 × $1,255.00
-
1 × $2,009.00
-
1 × $1,185.00
-
1 × $5,458.00
-
2 × $521.00
-
1 × $951.00
-
1 × $569.00
-
1 × $2,184.00
-
1 × $780.00
-
1 × $1,555.00
-
1 × $3,604.00
-
1 × $4,374.00
-
2 × $1,843.00
-
1 × $7,614.00
-
1 × $385.00
-
1 × $3,385.00
-
1 × $873.00
-
1 × $1,841.00
-
1 × $3,344.00
-
1 × $6,930.00
-
2 × $754.00
-
1 × $915.00
-
1 × $713.00
-
2 × $819.00
-
1 × $388.00
-
2 × $524.00
-
1 × $1,052.00
-
2 × $391.00
-
2 × $1,321.00
-
1 × $2,435.00
-
1 × $472.00
-
2 × $2,805.00
-
1 × $877.00
-
2 × $373.00
-
1 × $1,092.00
-
1 × $1,418.00
-
1 × $399.00
-
1 × $1,125.00
-
2 × $415.00
-
1 × $2,314.00
-
1 × $1,050.00
-
2 × $2,533.00
-
1 × $420.00
-
1 × $1,369.00
-
1 × $1,725.00
-
1 × $515.00
-
1 × $1,377.00
-
1 × $2,776.00
-
1 × $2,361.00
-
1 × $399.00
-
1 × $670.00
-
1 × $395.00
-
2 × $682.00
-
1 × $3,917.00
-
1 × $2,527.00
-
1 × $2,452.00
-
2 × $561.00
-
2 × $1,687.00
-
1 × $2,218.00
-
1 × $1,638.00
-
1 × $4,091.00
-
1 × $2,665.00
-
1 × $5,244.00
-
2 × $1,516.00
-
1 × $760.00
-
1 × $1,406.00
-
1 × $2,756.00
-
1 × $525.00
-
1 × $2,393.00
-
1 × $1,418.00
-
1 × $1,706.00
-
1 × $596.00
-
1 × $1,389.00
-
1 × $17,804.00
-
1 × $573.00
-
1 × $3,486.00
-
1 × $521.00
-
1 × $852.00
-
1 × $1,057.00
-
1 × $745.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty