3 × $444.00
-
2 × $4,968.00
-
1 × $4,119.00
-
1 × $555.00
-
1 × $2,738.00
-
2 × $1,585.00
-
3 × $3,544.00
-
1 × $3,286.00
-
4 × $1,389.00
-
1 × $2,790.00
-
3 × $2,223.00
-
1 × $3,417.00
-
1 × $4,382.00
-
1 × $5,820.00
-
3 × $573.00
-
1 × $947.00
-
1 × $2,782.00
-
3 × $399.00
-
1 × $395.00
-
1 × $713.00
-
1 × $720.00
-
2 × $492.00
-
1 × $471.00
-
1 × $3,411.00
-
1 × $755.00
-
2 × $569.00
-
4 × $2,724.00
-
1 × $1,625.00
-
1 × $538.00
-
2 × $573.00
-
1 × $416.00
-
1 × $608.00
-
3 × $391.00
-
4 × $373.00
-
3 × $484.00
-
2 × $1,819.00
-
1 × $954.00
-
1 × $1,511.00
-
3 × $819.00
-
1 × $3,227.00
-
2 × $682.00
-
1 × $1,266.00
-
1 × $521.00
-
1 × $573.00
-
2 × $682.00
-
1 × $471.00
-
1 × $1,887.00
-
1 × $1,421.00
-
1 × $5,861.00
-
1 × $3,778.00
-
1 × $1,489.00
-
2 × $616.00
-
1 × $20,652.00
-
1 × $712.00
-
1 × $613.00
-
1 × $813.00
-
2 × $1,467.00
-
2 × $760.00
-
1 × $915.00
-
1 × $3,385.00
-
1 × $1,970.00
-
1 × $2,218.00
-
1 × $1,687.00
-
1 × $471.00
-
1 × $1,665.00
-
1 × $753.00
-
2 × $4,091.00
-
1 × $7,754.00
-
1 × $2,184.00
-
1 × $430.00
-
1 × $887.00
-
1 × $1,337.00
-
2 × $5,458.00
-
2 × $520.00
-
1 × $2,361.00
-
1 × $819.00
-
1 × $425.00
-
2 × $788.00
-
1 × $401.00
-
1 × $524.00
-
2 × $855.00
-
1 × $2,164.00
-
2 × $897.00
-
1 × $491.00
-
1 × $397.00
-
1 × $706.00
-
1 × $1,904.00
-
CVSM 6800 - Blood Pressure, SpO2 (Nellcor), EarlySense, Temperature (Braun), Custom Scoring, Printer1 × $5,582.00
-
1 × $2,390.00
-
1 × $800.00
-
1 × $793.00
-
1 × $1,340.00
-
1 × $1,281.00
-
1 × $3,604.00
-
1 × $1,406.00
-
1 × $2,756.00
-
1 × $1,265.00
-
1 × $454.00
-
1 × $1,311.00
-
1 × $2,492.00
-
1 × $635.00
-
1 × $12,807.00
-
1 × $471.00
-
1 × $1,755.00
-
1 × $951.00
-
1 × $820.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty