1 × $1,457.00
-
2 × $547.00
-
2 × $1,516.00
-
1 × $5,036.00
-
1 × $1,034.00
-
1 × $3,486.00
-
1 × $437.00
-
1 × $1,394.00
-
1 × $2,223.00
-
3 × $706.00
-
2 × $613.00
-
1 × $2,361.00
-
1 × $399.00
-
1 × $575.00
-
1 × $818.00
-
1 × $1,337.00
-
2 × $1,970.00
-
1 × $2,390.00
-
1 × $1,598.00
-
1 × $1,185.00
-
1 × $1,819.00
-
1 × $656.00
-
1 × $954.00
-
1 × $530.00
-
2 × $1,340.00
-
1 × $1,177.00
-
1 × $1,198.00
-
1 × $1,018.00
-
1 × $2,314.00
-
1 × $1,081.00
-
1 × $760.00
-
1 × $2,133.00
-
1 × $573.00
-
1 × $25,527.00
-
1 × $525.00
-
3 × $2,009.00
-
1 × $608.00
-
2 × $2,724.00
-
1 × $3,604.00
-
1 × $2,361.00
-
1 × $894.00
-
1 × $682.00
-
1 × $20,652.00
-
1 × $466.00
-
1 × $1,389.00
-
1 × $1,642.00
-
1 × $1,406.00
-
1 × $569.00
-
1 × $1,281.00
-
1 × $783.00
-
2 × $1,005.00
-
1 × $2,531.00
-
1 × $403.00
-
1 × $3,931.00
-
1 × $712.00
-
1 × $1,130.00
-
1 × $1,224.00
-
1 × $852.00
-
1 × $830.00
-
1 × $425.00
-
2 × $570.00
-
1 × $5,458.00
-
1 × $2,218.00
-
1 × $877.00
-
1 × $1,218.00
-
2 × $1,718.00
-
2 × $768.00
-
1 × $416.00
-
1 × $1,311.00
-
1 × $2,424.00
-
2 × $3,778.00
-
1 × $2,492.00
-
1 × $1,562.00
-
1 × $997.00
-
1 × $1,238.00
-
1 × $1,548.00
-
1 × $1,575.00
-
1 × $673.00
-
1 × $467.00
-
1 × $581.00
-
1 × $855.00
-
1 × $841.00
-
1 × $3,411.00
-
1 × $1,687.00
-
1 × $713.00
-
1 × $521.00
-
1 × $2,436.00
-
1 × $3,067.00
-
1 × $682.00
-
1 × $897.00
-
1 × $2,805.00
-
1 × $4,091.00
-
1 × $820.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty