-
2 × $492.00
-
1 × $399.00
-
3 × $2,435.00
-
1 × $1,819.00
-
2 × $608.00
-
3 × $454.00
-
1 × $521.00
-
4 × $484.00
-
1 × $2,361.00
-
1 × $395.00
-
2 × $401.00
-
1 × $403.00
-
1 × $1,643.00
-
1 × $1,095.00
-
1 × $3,917.00
-
1 × $573.00
-
1 × $1,223.00
-
1 × $457.00
-
1 × $4,065.00
-
1 × $760.00
-
1 × $13,010.00
-
1 × $547.00
-
1 × $1,086.00
-
1 × $877.00
-
2 × $524.00
-
1 × $613.00
-
1 × $2,393.00
-
1 × $706.00
-
3 × $573.00
-
1 × $25,527.00
-
3 × $819.00
-
1 × $1,309.00
-
2 × $3,604.00
-
1 × $561.00
-
2 × $1,389.00
-
1 × $1,322.00
-
2 × $2,009.00
-
1 × $3,723.00
-
1 × $2,390.00
-
1 × $385.00
-
3 × $1,034.00
-
1 × $1,147.00
-
1 × $544.00
-
1 × $1,117.00
-
2 × $581.00
-
1 × $1,725.00
-
2 × $399.00
-
1 × $3,051.00
-
1 × $2,361.00
-
1 × $560.00
-
2 × $2,436.00
-
2 × $1,970.00
-
3 × $1,467.00
-
1 × $680.00
-
1 × $415.00
-
1 × $1,113.00
-
2 × $403.00
-
1 × $388.00
-
1 × $3,411.00
-
2 × $520.00
-
1 × $4,091.00
-
2 × $573.00
-
2 × $897.00
-
2 × $2,361.00
-
1 × $481.00
-
2 × $1,111.00
-
1 × $607.00
-
1 × $3,601.00
-
1 × $2,452.00
-
1 × $1,510.00
-
1 × $882.00
-
1 × $745.00
-
1 × $2,956.00
-
2 × $538.00
-
1 × $1,052.00
-
1 × $2,756.00
-
1 × $3,237.00
-
2 × $855.00
-
1 × $3,530.00
-
1 × $682.00
-
1 × $477.00
-
1 × $2,184.00
-
1 × $5,458.00
-
1 × $554.00
-
1 × $455.00
-
1 × $784.00
-
1 × $2,190.00
-
1 × $2,533.00
-
1 × $1,237.00
-
1 × $3,917.00
-
1 × $682.00
-
1 × $24,377.00
-
2 × $1,575.00
-
1 × $1,843.00
-
1 × $3,486.00
-
1 × $5,820.00
-
1 × $2,774.00
-
1 × $2,184.00
-
1 × $4,645.00
-
1 × $1,516.00
-
1 × $373.00
-
1 × $1,511.00
-
1 × $1,029.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty