2 × $537.00
-
2 × $524.00
-
1 × $1,725.00
-
2 × $830.00
-
2 × $706.00
-
3 × $784.00
-
1 × $1,896.00
-
1 × $4,968.00
-
1 × $1,337.00
-
1 × $4,374.00
-
1 × $887.00
-
1 × $539.00
-
1 × $3,931.00
-
1 × $388.00
-
2 × $1,990.00
-
1 × $3,416.00
-
1 × $812.00
-
1 × $13,010.00
-
1 × $1,985.00
-
2 × $942.00
-
2 × $1,718.00
-
1 × $788.00
-
2 × $680.00
-
1 × $437.00
-
1 × $3,472.00
-
1 × $457.00
-
2 × $399.00
-
2 × $2,436.00
-
1 × $712.00
-
2 × $1,440.00
-
1 × $521.00
-
2 × $2,492.00
-
1 × $470.00
-
3 × $1,585.00
-
1 × $1,642.00
-
1 × $8,734.00
-
1 × $1,819.00
-
1 × $607.00
-
1 × $1,311.00
-
1 × $5,222.00
-
1 × $2,832.00
-
1 × $1,548.00
-
1 × $2,485.00
-
1 × $554.00
-
1 × $573.00
-
1 × $839.00
-
1 × $1,068.00
-
1 × $416.00
-
1 × $410.00
-
1 × $1,665.00
-
1 × $538.00
-
2 × $2,452.00
-
1 × $3,237.00
-
2 × $813.00
-
1 × $1,642.00
-
1 × $582.00
-
1 × $997.00
-
1 × $1,191.00
-
2 × $1,091.00
-
1 × $2,314.00
-
1 × $3,486.00
-
1 × $1,369.00
-
1 × $388.00
-
1 × $2,390.00
-
1 × $1,237.00
-
1 × $5,458.00
-
1 × $2,297.00
-
2 × $1,706.00
-
1 × $515.00
-
1 × $677.00
-
1 × $6,360.00
-
1 × $467.00
-
2 × $2,782.00
-
1 × $401.00
-
1 × $1,467.00
-
1 × $1,843.00
-
1 × $616.00
-
1 × $2,929.00
-
1 × $1,793.00
-
1 × $852.00
-
1 × $561.00
-
1 × $454.00
-
1 × $819.00
-
1 × $1,418.00
-
1 × $1,406.00
-
1 × $487.00
-
1 × $1,575.00
-
1 × $816.00
-
1 × $3,604.00
-
1 × $5,003.00
-
1 × $583.00
-
1 × $7,614.00
-
1 × $7,433.00
-
1 × $720.00
-
1 × $1,340.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty