1 × $1,073.00
-
1 × $2,223.00
-
1 × $3,486.00
-
1 × $561.00
-
1 × $3,416.00
-
1 × $435.00
-
4 × $951.00
-
2 × $670.00
-
1 × $2,184.00
-
1 × $3,931.00
-
2 × $1,111.00
-
1 × $538.00
-
1 × $1,068.00
-
2 × $608.00
-
3 × $760.00
-
1 × $765.00
-
1 × $454.00
-
1 × $1,575.00
-
1 × $725.00
-
1 × $642.00
-
1 × $399.00
-
1 × $2,736.00
-
2 × $385.00
-
3 × $401.00
-
3 × $2,492.00
-
2 × $573.00
-
2 × $2,452.00
-
1 × $398.00
-
2 × $897.00
-
1 × $1,311.00
-
1 × $20,652.00
-
1 × $561.00
-
1 × $3,417.00
-
1 × $466.00
-
1 × $3,067.00
-
1 × $403.00
-
1 × $3,286.00
-
1 × $1,967.07
-
4 × $1,585.00
-
1 × $2,190.00
-
1 × $521.00
-
1 × $3,567.00
-
1 × $1,562.00
-
2 × $2,435.00
-
1 × $1,309.00
-
3 × $2,436.00
-
1 × $575.00
-
1 × $1,019.00
-
1 × $373.00
-
2 × $2,218.00
-
1 × $4,645.00
-
1 × $607.00
-
1 × $2,009.00
-
3 × $521.00
-
2 × $2,533.00
-
1 × $24,648.00
-
1 × $437.00
-
1 × $2,390.00
-
1 × $444.00
-
1 × $403.00
-
1 × $17,804.00
-
1 × $1,725.00
-
1 × $2,200.00
-
3 × $524.00
-
1 × $1,467.00
-
1 × $2,790.00
-
1 × $415.00
-
1 × $673.00
-
1 × $1,255.00
-
1 × $1,257.00
-
1 × $2,782.00
-
1 × $915.00
-
1 × $2,805.00
-
1 × $855.00
-
1 × $1,990.00
-
1 × $8,091.00
-
2 × $1,281.00
-
1 × $2,361.00
-
1 × $819.00
-
1 × $18,348.00
-
1 × $830.00
-
1 × $399.00
-
1 × $788.00
-
1 × $1,706.00
-
1 × $477.00
-
1 × $3,218.00
-
2 × $1,516.00
-
1 × $24,377.00
-
1 × $682.00
-
1 × $1,191.00
-
2 × $581.00
-
1 × $555.00
-
1 × $877.00
-
1 × $1,052.00
-
1 × $1,555.00
-
2 × $573.00
-
2 × $2,314.00
-
1 × $2,190.00
-
1 × $467.00
-
1 × $446.00
-
1 × $682.00
-
1 × $484.00
-
1 × $3,604.00
-
1 × $2,184.00
-
1 × $698.00
-
1 × $1,841.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty