1 × $2,390.00
-
1 × $4,645.00
-
1 × $492.00
-
1 × $385.00
-
1 × $1,575.00
-
1 × $1,421.00
-
2 × $537.00
-
3 × $1,970.00
-
1 × $471.00
-
2 × $2,361.00
-
1 × $2,790.00
-
2 × $521.00
-
1 × $915.00
-
2 × $608.00
-
1 × $403.00
-
2 × $1,642.00
-
2 × $399.00
-
1 × $1,440.00
-
1 × $399.00
-
2 × $373.00
-
1 × $2,560.00
-
2 × $525.00
-
1 × $852.00
-
1 × $1,068.00
-
1 × $530.00
-
1 × $1,516.00
-
1 × $896.00
-
1 × $2,361.00
-
2 × $897.00
-
1 × $1,337.00
-
3 × $706.00
-
2 × $403.00
-
2 × $454.00
-
1 × $471.00
-
2 × $941.00
-
1 × $720.00
-
1 × $2,776.00
-
1 × $2,218.00
-
1 × $1,642.00
-
2 × $1,819.00
-
1 × $670.00
-
1 × $951.00
-
2 × $613.00
-
1 × $1,826.00
-
2 × $682.00
-
1 × $2,452.00
-
1 × $524.00
-
1 × $3,416.00
-
1 × $573.00
-
1 × $3,237.00
-
1 × $1,278.00
-
1 × $1,555.00
-
2 × $521.00
-
1 × $1,843.00
-
1 × $24,377.00
-
1 × $820.00
-
3 × $561.00
-
1 × $457.00
-
1 × $3,385.00
-
1 × $4,437.00
-
1 × $1,224.00
-
1 × $3,486.00
-
1 × $2,184.00
-
1 × $1,642.00
-
1 × $25,527.00
-
1 × $554.00
-
1 × $740.00
-
1 × $467.00
-
1 × $839.00
-
2 × $2,957.00
-
1 × $1,839.00
-
1 × $819.00
-
1 × $3,604.00
-
2 × $603.00
-
1 × $2,361.00
-
2 × $607.00
-
1 × $2,184.00
-
1 × $560.00
-
2 × $3,544.00
-
2 × $616.00
-
1 × $3,778.00
-
1 × $2,314.00
-
1 × $3,244.00
-
1 × $1,034.00
-
1 × $2,724.00
-
1 × $858.00
-
1 × $425.00
-
1 × $471.00
-
1 × $652.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty