1 × $569.00
-
4 × $784.00
-
2 × $521.00
-
1 × $16,982.00
-
3 × $1,237.00
-
2 × $613.00
-
1 × $561.00
-
3 × $819.00
-
2 × $537.00
-
1 × $603.00
-
1 × $1,278.00
-
2 × $760.00
-
5 × $1,191.00
-
1 × $712.00
-
1 × $2,124.00
-
4 × $2,452.00
-
3 × $2,724.00
-
2 × $682.00
-
2 × $830.00
-
2 × $520.00
-
3 × $1,990.00
-
3 × $1,255.00
-
1 × $1,091.00
-
1 × $640.00
-
1 × $550.00
-
2 × $403.00
-
1 × $401.00
-
3 × $1,191.00
-
2 × $8,984.00
-
4 × $373.00
-
3 × $682.00
-
3 × $858.00
-
1 × $573.00
-
1 × $1,265.00
-
4 × $573.00
-
1 × $772.00
-
1 × $3,237.00
-
1 × $17,804.00
-
1 × $764.00
-
4 × $1,819.00
-
2 × $399.00
-
1 × $416.00
-
1 × $1,406.00
-
1 × $608.00
-
1 × $1,516.00
-
1 × $1,970.00
-
4 × $403.00
-
1 × $403.00
-
1 × $2,830.00
-
1 × $813.00
-
1 × $4,374.00
-
2 × $680.00
-
3 × $1,718.00
-
1 × $3,723.00
-
2 × $484.00
-
3 × $788.00
-
1 × $2,393.00
-
1 × $1,034.00
-
2 × $391.00
-
1 × $2,184.00
-
1 × $573.00
-
4 × $395.00
-
2 × $442.00
-
1 × $628.00
-
1 × $569.00
-
1 × $1,113.00
-
1 × $1,257.00
-
1 × $1,793.00
-
1 × $2,184.00
-
1 × $3,416.00
-
1 × $538.00
-
2 × $554.00
-
3 × $530.00
-
1 × $555.00
-
2 × $951.00
-
1 × $579.00
-
1 × $5,086.00
-
1 × $650.00
-
1 × $915.00
-
4 × $399.00
-
1 × $3,544.00
-
1 × $4,065.00
-
1 × $1,309.00
-
1 × $706.00
-
1 × $3,917.00
-
1 × $25,527.00
-
2 × $581.00
-
1 × $1,752.00
-
1 × $2,009.00
-
1 × $2,436.00
-
1 × $20,652.00
-
1 × $2,390.00
-
2 × $1,377.00
-
1 × $2,400.00
-
1 × $524.00
-
1 × $454.00
-
1 × $1,218.00
-
1 × $438.00
-
1 × $3,530.00
-
1 × $2,782.00
-
1 × $2,805.00
-
1 × $477.00
-
1 × $754.00
-
1 × $2,361.00
-
1 × $522.00
-
1 × $960.00
-
1 × $2,435.00
-
1 × $819.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty