1 × $401.00
-
1 × $784.00
-
3 × $1,255.00
-
3 × $3,778.00
-
2 × $416.00
-
2 × $2,776.00
-
3 × $1,516.00
-
1 × $5,861.00
-
2 × $819.00
-
2 × $581.00
-
1 × $1,041.00
-
2 × $2,184.00
-
1 × $403.00
-
1 × $399.00
-
1 × $1,158.00
-
2 × $3,411.00
-
2 × $852.00
-
1 × $2,531.00
-
2 × $520.00
-
2 × $2,724.00
-
1 × $1,226.00
-
2 × $682.00
-
1 × $2,492.00
-
1 × $2,361.00
-
2 × $2,218.00
-
1 × $1,643.00
-
2 × $401.00
-
1 × $575.00
-
3 × $819.00
-
1 × $608.00
-
1 × $616.00
-
2 × $1,389.00
-
2 × $3,237.00
-
1 × $682.00
-
1 × $1,971.00
-
2 × $521.00
-
1 × $877.00
-
1 × $673.00
-
4 × $4,968.00
-
1 × $1,185.00
-
1 × $706.00
-
1 × $6,406.00
-
1 × $628.00
-
1 × $837.00
-
1 × $704.00
-
1 × $471.00
-
1 × $1,282.00
-
1 × $1,887.00
-
1 × $1,511.00
-
1 × $1,095.00
-
1 × $2,050.00
-
1 × $570.00
-
1 × $786.00
-
1 × $1,087.00
-
1 × $2,435.00
-
1 × $2,184.00
-
1 × $1,139.00
-
1 × $525.00
-
2 × $876.00
-
1 × $530.00
-
1 × $2,223.00
-
1 × $2,436.00
-
3 × $642.00
-
2 × $1,990.00
-
1 × $1,511.00
-
1 × $521.00
-
1 × $479.00
-
1 × $524.00
-
1 × $3,344.00
-
1 × $547.00
-
2 × $2,929.00
-
1 × $397.00
-
1 × $1,793.00
-
1 × $477.00
-
1 × $7,433.00
-
1 × $1,440.00
-
1 × $772.00
-
1 × $1,257.00
-
1 × $4,134.00
-
1 × $1,206.00
-
1 × $897.00
-
1 × $1,208.00
-
1 × $2,361.00
-
1 × $437.00
-
1 × $469.00
-
1 × $947.00
-
1 × $2,168.00
-
1 × $1,843.00
-
1 × $1,687.00
-
1 × $1,585.00
-
1 × $1,819.00
-
1 × $656.00
-
1 × $725.00
-
1 × $471.00
-
1 × $4,382.00
-
1 × $490.00
-
1 × $487.00
-
1 × $25,527.00
-
1 × $2,163.00
-
1 × $3,544.00
-
1 × $466.00
-
1 × $4,065.00
Phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Included Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty