1 × $2,834.00
-
1 × $1,139.00
-
1 × $1,340.00
-
1 × $569.00
-
1 × $2,492.00
-
1 × $1,106.00
-
1 × $530.00
-
1 × $1,642.00
-
2 × $2,361.00
-
1 × $1,562.00
-
2 × $1,643.00
-
1 × $3,723.00
-
1 × $1,191.00
-
2 × $656.00
-
3 × $2,223.00
-
2 × $524.00
-
1 × $1,018.00
-
1 × $820.00
-
1 × $1,638.00
-
2 × $573.00
-
1 × $560.00
-
1 × $3,931.00
-
1 × $877.00
-
1 × $398.00
-
1 × $2,361.00
-
1 × $616.00
-
1 × $471.00
-
1 × $442.00
-
1 × $430.00
-
2 × $521.00
-
1 × $1,826.00
-
1 × $2,050.00
-
1 × $1,086.00
-
2 × $1,575.00
-
1 × $435.00
-
1 × $788.00
-
1 × $403.00
-
2 × $3,604.00
-
1 × $1,750.00
-
1 × $754.00
-
1 × $819.00
-
1 × $1,153.00
-
1 × $471.00
-
1 × $399.00
-
1 × $2,756.00
-
1 × $7,614.00
-
1 × $477.00
-
2 × $951.00
-
1 × $399.00
-
2 × $670.00
-
1 × $1,819.00
-
1 × $1,035.00
-
1 × $897.00
-
1 × $1,487.00
-
1 × $1,642.00
-
1 × $1,642.00
-
1 × $2,184.00
-
2 × $1,406.00
-
1 × $2,042.00
-
1 × $837.00
-
1 × $960.00
-
1 × $1,255.00
-
1 × $4,382.00
-
1 × $2,452.00
-
1 × $642.00
-
1 × $608.00
-
2 × $3,778.00
-
1 × $537.00
-
1 × $1,052.00
-
1 × $793.00
-
1 × $819.00
-
2 × $521.00
-
1 × $816.00
-
1 × $2,361.00
-
1 × $20,652.00
-
2 × $4,050.00
-
1 × $768.00
-
1 × $4,355.00
-
1 × $567.00
-
1 × $1,034.00
-
1 × $915.00
-
1 × $2,776.00
-
1 × $628.00
-
2 × $3,416.00
-
2 × $25,527.00
-
1 × $1,970.00
-
1 × $682.00
-
1 × $561.00
-
1 × $2,218.00
-
1 × $676.00
-
1 × $1,092.00
-
1 × $740.00
-
1 × $1,091.00
-
1 × $852.00
-
1 × $3,417.00
-
1 × $1,257.00
-
1 × $3,411.00
-
1 × $1,092.00
-
1 × $373.00
-
1 × $1,440.00
-
1 × $391.00
-
1 × $404.00
-
1 × $1,202.00
-
1 × $1,511.00
-
1 × $680.00
-
1 × $849.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information
- 1-Year Warranty