1 × $820.00
-
1 × $560.00
-
1 × $947.00
-
3 × $608.00
-
1 × $5,153.00
-
1 × $706.00
-
1 × $573.00
-
1 × $2,223.00
-
1 × $704.00
-
1 × $20,652.00
-
1 × $581.00
-
1 × $3,385.00
-
1 × $399.00
-
3 × $1,718.00
-
1 × $997.00
-
1 × $954.00
-
2 × $444.00
-
1 × $2,190.00
-
1 × $1,440.00
-
2 × $3,067.00
-
1 × $2,361.00
-
1 × $6,360.00
-
2 × $547.00
-
1 × $2,190.00
-
1 × $4,065.00
-
1 × $391.00
-
1 × $877.00
-
1 × $788.00
-
1 × $613.00
-
1 × $1,164.00
-
1 × $5,036.00
-
1 × $2,184.00
-
1 × $818.00
-
1 × $1,218.00
-
2 × $2,452.00
-
1 × $3,931.00
-
1 × $1,819.00
-
1 × $1,687.00
-
2 × $839.00
-
1 × $1,862.00
-
1 × $2,790.00
-
2 × $2,492.00
-
1 × $968.00
-
3 × $520.00
-
1 × $454.00
-
1 × $3,778.00
-
1 × $1,271.00
-
1 × $2,782.00
-
1 × $2,929.00
-
1 × $712.00
-
3 × $5,458.00
-
1 × $819.00
-
1 × $2,724.00
-
1 × $1,752.00
-
1 × $656.00
-
2 × $373.00
-
1 × $1,510.00
-
1 × $1,841.00
-
1 × $3,704.00
-
1 × $537.00
-
1 × $1,255.00
-
3 × $849.00
-
1 × $855.00
-
2 × $561.00
-
1 × $2,057.00
-
1 × $1,309.00
-
1 × $2,738.00
-
2 × $2,805.00
-
1 × $1,575.00
-
1 × $698.00
-
1 × $403.00
-
1 × $2,520.00
-
1 × $652.00
-
1 × $819.00
-
1 × $3,723.00
-
2 × $579.00
-
1 × $682.00
-
1 × $3,237.00
-
1 × $13,010.00
-
1 × $3,416.00
-
1 × $2,776.00
-
1 × $525.00
-
1 × $1,848.00
-
1 × $25,527.00
-
1 × $1,068.00
-
1 × $471.00
-
1 × $2,218.00
-
1 × $2,164.00
-
1 × $1,237.00
-
1 × $442.00
-
1 × $4,355.00
-
1 × $1,511.00
-
1 × $673.00
-
1 × $760.00
-
1 × $1,340.00
-
1 × $887.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information
- 1-Year Warranty