3 × $682.00
-
1 × $706.00
-
1 × $1,113.00
-
3 × $819.00
-
2 × $3,237.00
-
4 × $573.00
-
2 × $13,010.00
-
2 × $2,218.00
-
4 × $616.00
-
4 × $682.00
-
1 × $559.00
-
1 × $1,418.00
-
1 × $2,492.00
-
1 × $858.00
-
1 × $813.00
-
2 × $4,696.00
-
1 × $1,642.00
-
3 × $1,467.00
-
2 × $391.00
-
1 × $2,805.00
-
1 × $403.00
-
1 × $1,377.00
-
1 × $588.00
-
2 × $4,355.00
-
1 × $471.00
-
1 × $5,861.00
-
1 × $442.00
-
1 × $2,050.00
-
1 × $740.00
-
2 × $2,782.00
-
1 × $457.00
-
1 × $607.00
-
2 × $554.00
-
1 × $1,202.00
-
1 × $6,360.00
-
1 × $4,968.00
-
1 × $395.00
-
1 × $3,385.00
-
2 × $673.00
-
1 × $492.00
-
1 × $3,723.00
-
2 × $1,440.00
-
1 × $855.00
-
1 × $2,724.00
-
2 × $897.00
-
1 × $2,223.00
-
2 × $1,218.00
-
1 × $1,718.00
-
2 × $561.00
-
1 × $628.00
-
1 × $755.00
-
1 × $1,548.00
-
1 × $1,038.00
-
6 × $1,516.00
-
1 × $1,687.00
-
1 × $438.00
-
1 × $1,848.00
-
1 × $2,188.00
-
1 × $573.00
-
1 × $608.00
-
2 × $2,531.00
-
4 × $373.00
-
1 × $1,421.00
-
1 × $24,377.00
-
1 × $1,990.00
-
3 × $454.00
-
1 × $1,223.00
-
1 × $3,544.00
-
1 × $2,265.00
-
1 × $403.00
-
5 × $1,819.00
-
1 × $3,604.00
-
1 × $740.00
-
1 × $830.00
-
1 × $547.00
-
1 × $1,638.00
-
3 × $642.00
-
1 × $3,917.00
-
1 × $685.00
-
1 × $2,009.00
-
1 × $1,750.00
-
1 × $2,057.00
-
3 × $5,458.00
-
1 × $520.00
-
1 × $1,091.00
-
2 × $852.00
-
1 × $2,390.00
-
1 × $712.00
-
3 × $524.00
-
2 × $2,184.00
-
2 × $613.00
-
1 × $1,018.00
-
1 × $575.00
-
1 × $1,206.00
-
1 × $399.00
-
1 × $685.00
-
1 × $4,645.00
-
1 × $1,720.00
-
1 × $2,076.00
-
1 × $1,322.00
-
1 × $818.00
-
1 × $521.00
-
1 × $4,065.00
-
1 × $1,642.00
-
1 × $1,511.00
-
1 × $444.00
-
1 × $1,575.00
-
1 × $397.00
-
1 × $520.00
-
1 × $17,804.00
-
1 × $754.00
-
1 × $2,435.00
-
1 × $20,652.00
-
1 × $1,389.00
-
1 × $725.00
-
1 × $16,982.00
-
1 × $2,219.00
-
1 × $1,191.00
-
1 × $471.00
-
1 × $521.00
-
1 × $656.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information