2 × $1,516.00
-
2 × $682.00
-
1 × $554.00
-
2 × $760.00
-
1 × $986.00
-
2 × $1,255.00
-
3 × $1,970.00
-
1 × $784.00
-
1 × $454.00
-
1 × $3,411.00
-
1 × $573.00
-
1 × $1,839.00
-
2 × $537.00
-
1 × $467.00
-
2 × $3,237.00
-
1 × $855.00
-
1 × $385.00
-
2 × $5,226.00
-
1 × $1,752.00
-
1 × $816.00
-
1 × $524.00
-
1 × $1,052.00
-
1 × $656.00
-
1 × $1,092.00
-
1 × $5,036.00
-
1 × $4,091.00
-
1 × $832.00
-
1 × $373.00
-
1 × $3,417.00
-
2 × $682.00
-
1 × $1,990.00
-
1 × $4,664.00
-
1 × $403.00
-
1 × $1,068.00
-
1 × $3,872.00
-
2 × $1,718.00
-
2 × $852.00
-
1 × $1,111.00
-
2 × $3,385.00
-
1 × $520.00
-
1 × $1,281.00
-
1 × $2,520.00
-
1 × $2,184.00
-
1 × $2,782.00
-
1 × $2,492.00
-
1 × $569.00
-
1 × $492.00
-
1 × $2,533.00
-
1 × $560.00
-
1 × $1,278.00
-
1 × $3,486.00
-
2 × $4,968.00
-
1 × $1,725.00
-
1 × $579.00
-
1 × $416.00
-
1 × $2,142.00
-
1 × $887.00
-
1 × $712.00
-
2 × $2,390.00
-
1 × $793.00
-
1 × $7,735.00
-
1 × $3,416.00
-
3 × $788.00
-
1 × $2,314.00
-
1 × $9,284.00
-
1 × $521.00
-
1 × $3,344.00
-
2 × $951.00
-
1 × $538.00
-
1 × $1,457.00
-
1 × $3,218.00
-
1 × $830.00
-
1 × $1,197.00
-
1 × $3,385.00
-
1 × $3,917.00
-
1 × $3,035.00
-
1 × $468.00
-
1 × $1,394.00
-
1 × $4,065.00
-
1 × $1,826.00
-
1 × $2,184.00
-
1 × $706.00
-
1 × $2,184.00
-
1 × $740.00
-
1 × $13,010.00
-
1 × $613.00
-
1 × $1,593.00
-
1 × $487.00
-
1 × $470.00
-
1 × $1,179.00
The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters) Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case (08-120)
Technical Specifications
- Main cylinder:
- Inside cylinder diameter: 140 mm
- Inside cylinder height: 150 mm
- Cylinder wall thickness: 6 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 40 mm
- Cold spheres:
- Solid sphere diameters: 3.2, 4.8, 9.5, 12.7, 15.9 and 19.1 mm
- Height of the center of the spheres from the base plate: 78.5 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 4, 6, 8, 12, 16 mm
- PTFE solid cylinder diameter: 16 mm
- Cylinder height: 25.4 mm
Warranty Information