6 × $573.00
-
5 × $3,931.00
-
1 × $2,513.00
-
3 × $1,309.00
-
1 × $1,086.00
-
2 × $1,418.00
-
2 × $608.00
-
2 × $1,638.00
-
1 × $673.00
-
4 × $1,111.00
-
1 × $2,998.00
-
1 × $525.00
-
1 × $1,105.00
-
3 × $3,486.00
-
4 × $573.00
-
5 × $1,052.00
-
1 × $2,520.00
-
3 × $4,065.00
-
4 × $3,604.00
-
3 × $477.00
-
1 × $784.00
-
2 × $2,805.00
-
2 × $788.00
-
3 × $561.00
-
1 × $1,750.00
-
2 × $1,752.00
-
1 × $5,458.00
-
1 × $399.00
-
2 × $538.00
-
1 × $4,678.00
-
1 × $1,191.00
-
2 × $682.00
-
1 × $997.00
-
3 × $391.00
-
1 × $720.00
-
2 × $403.00
-
1 × $442.00
-
2 × $573.00
-
1 × $1,022.00
-
1 × $476.00
-
1 × $1,947.00
-
3 × $2,452.00
-
1 × $1,345.00
-
1 × $608.00
-
2 × $395.00
-
1 × $819.00
-
1 × $1,577.00
-
2 × $1,725.00
-
1 × $951.00
-
2 × $492.00
-
4 × $1,516.00
-
1 × $20,652.00
-
1 × $1,531.00
-
1 × $569.00
-
1 × $1,073.00
-
2 × $575.00
-
1 × $521.00
-
2 × $1,237.00
-
1 × $1,990.00
-
1 × $2,433.00
-
1 × $398.00
-
1 × $858.00
-
1 × $1,014.00
-
1 × $24,377.00
-
1 × $2,050.00
-
1 × $521.00
-
1 × $1,013.00
-
1 × $2,520.00
-
1 × $3,917.00
-
1 × $1,255.00
-
1 × $388.00
-
1 × $554.00
-
1 × $680.00
-
1 × $3,067.00
-
1 × $415.00
-
1 × $706.00
-
1 × $1,638.00
The phantom for high resolution NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty