1 × $2,520.00
-
1 × $2,042.00
-
3 × $388.00
-
12 × $373.00
-
1 × $642.00
-
1 × $1,322.00
-
1 × $6,360.00
-
1 × $3,108.00
-
2 × $1,257.00
-
15 × $682.00
-
3 × $1,418.00
-
1 × $720.00
-
1 × $521.00
-
4 × $858.00
-
1 × $1,068.00
-
6 × $682.00
-
4 × $608.00
-
1 × $399.00
-
3 × $3,486.00
-
1 × $1,281.00
-
1 × $403.00
-
1 × $633.00
-
4 × $1,052.00
-
1 × $830.00
-
4 × $2,314.00
-
1 × $3,931.00
-
5 × $573.00
-
1 × $1,224.00
-
2 × $877.00
-
1 × $467.00
-
1 × $670.00
-
3 × $1,091.00
-
2 × $1,191.00
-
1 × $2,286.00
-
1 × $2,223.00
-
3 × $1,237.00
-
1 × $451.00
-
1 × $385.00
-
1 × $2,390.00
-
1 × $2,782.00
-
1 × $2,492.00
-
2 × $4,645.00
-
2 × $1,050.00
-
3 × $538.00
-
2 × $2,805.00
-
9 × $1,516.00
-
2 × $760.00
-
1 × $3,244.00
-
2 × $581.00
-
1 × $2,184.00
-
2 × $1,440.00
-
1 × $1,202.00
-
2 × $1,191.00
-
1 × $575.00
-
2 × $2,452.00
-
1 × $673.00
-
1 × $1,275.00
-
1 × $395.00
-
1 × $894.00
-
3 × $492.00
-
2 × $784.00
-
1 × $2,009.00
-
1 × $812.00
-
1 × $657.00
-
2 × $391.00
-
2 × $547.00
-
2 × $813.00
-
1 × $1,462.00
-
1 × $3,417.00
-
2 × $415.00
-
1 × $887.00
-
1 × $20,652.00
-
1 × $819.00
-
1 × $1,990.00
-
1 × $4,374.00
-
1 × $951.00
-
2 × $477.00
-
1 × $569.00
-
1 × $3,604.00
-
1 × $537.00
-
1 × $1,720.00
-
1 × $521.00
-
1 × $1,665.00
-
1 × $1,510.00
-
2 × $4,968.00
-
1 × $530.00
-
1 × $852.00
-
1 × $388.00
-
1 × $2,920.00
-
1 × $2,190.00
-
1 × $1,340.00
-
1 × $7,751.00
-
1 × $1,337.00
-
1 × $2,184.00
-
1 × $896.00
-
1 × $772.00
-
1 × $698.00
The phantom for high resolution NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty