-
1 × $3,106.00
-
3 × $4,374.00
-
14 × $373.00
-
11 × $1,516.00
-
1 × $1,169.00
-
11 × $573.00
-
1 × $7,735.00
-
1 × $3,124.00
-
3 × $673.00
-
3 × $1,091.00
-
3 × $530.00
-
2 × $521.00
-
1 × $477.00
-
1 × $470.00
-
1 × $2,009.00
-
2 × $442.00
-
3 × $698.00
-
2 × $385.00
-
2 × $1,052.00
-
2 × $3,237.00
-
16 × $682.00
-
2 × $521.00
-
1 × $788.00
-
3 × $403.00
-
2 × $819.00
-
2 × $2,400.00
-
1 × $445.00
-
1 × $20,652.00
-
2 × $849.00
-
1 × $1,185.00
-
5 × $1,191.00
-
1 × $1,191.00
-
1 × $1,401.00
-
9 × $608.00
-
2 × $3,417.00
-
9 × $682.00
-
1 × $819.00
-
3 × $784.00
-
1 × $20,652.00
-
1 × $457.00
-
10 × $760.00
-
2 × $547.00
-
1 × $3,051.00
-
1 × $3,370.00
-
2 × $680.00
-
1 × $3,834.00
-
1 × $820.00
-
6 × $2,314.00
-
1 × $403.00
-
1 × $656.00
-
1 × $1,031.00
-
3 × $1,179.00
-
1 × $2,813.00
-
1 × $1,337.00
-
1 × $403.00
-
2 × $525.00
-
2 × $813.00
-
1 × $1,281.00
-
1 × $852.00
-
1 × $391.00
-
1 × $395.00
-
1 × $2,452.00
-
1 × $1,265.00
-
1 × $3,416.00
-
1 × $1,585.00
-
1 × $486.00
-
3 × $3,917.00
-
3 × $1,575.00
-
1 × $621.00
-
3 × $1,255.00
-
1 × $1,068.00
-
2 × $1,687.00
-
1 × $1,323.00
-
2 × $5,458.00
-
1 × $538.00
-
1 × $573.00
-
2 × $3,486.00
-
2 × $3,604.00
-
1 × $492.00
-
1 × $1,309.00
-
1 × $2,533.00
-
1 × $2,782.00
-
1 × $1,725.00
-
2 × $1,237.00
-
1 × $3,244.00
-
1 × $581.00
-
1 × $1,440.00
-
1 × $1,340.00
-
1 × $7,433.00
-
1 × $4,968.00
-
1 × $855.00
-
1 × $1,060.00
-
1 × $830.00
-
1 × $1,990.00
-
1 × $616.00
-
1 × $2,184.00
-
1 × $1,841.00
-
3 × $415.00
-
1 × $569.00
-
1 × $1,642.00
-
1 × $8,869.00
-
1 × $1,638.00
-
1 × $561.00
-
1 × $538.00
-
1 × $2,435.00
The phantom for high resolution NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). Among other things, it can be used to evaluate: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
Features and Benefits
- Complies with:
- NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras
- AAPM Report No. 9 – Computer Aided Scintillation Camera Acceptance Testing
- AAPM Report No. 22 – Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control
- ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- The manual provides detailed guidelines for carrying out each test, results assessment and registration
- Optional Heavy Duty Carrying Case
Technical Specifications
- Main cylinder:
- Inside Cylinder Diameter: 206 mm
- Inside Cylinder Height: 186 mm
- Cylinder Wall Thickness: 7 mm
- Cold rods insert:
- Rod diameters: 3.2, 4.8, 6.4, 7.9, 9.5 and 11.1 mm
- Height of rods: 88 mm
- Cold Spheres:
- Solid Sphere Diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8 mm
- Height of the center of the spheres from the base plate: 127 mm
- Optional PET Lid with cylindrical samples:
- Refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- Water filled cylinder diameter: 25 mm
- Air filled cylinder diameter: 25 mm
- PTFE solid cylinder diameter: 25 mm
- Cylinder height: 38 mm
Warranty Information
- 1-Year Warranty