-
1 × $4,300.00
-
2 × $2,810.00
-
1 × $1,095.00
-
1 × $896.00
-
1 × $5,197.00
-
1 × $760.00
-
1 × $915.00
-
1 × $521.00
-
1 × $1,757.00
-
1 × $1,068.00
-
1 × $4,063.00
-
2 × $1,092.00
-
1 × $2,225.00
-
1 × $547.00
-
1 × $740.00
-
1 × $1,135.00
-
1 × $435.00
-
1 × $1,040.00
-
1 × $685.00
-
1 × $3,931.00
-
1 × $420.00
-
1 × $388.00
-
1 × $1,255.00
-
1 × $3,451.00
-
1 × $3,604.00
-
1 × $554.00
-
1 × $437.00
-
1 × $14,869.00
-
1 × $1,809.00
-
1 × $5,458.00
-
1 × $476.00
-
1 × $1,068.00
-
1 × $858.00
-
1 × $4,535.00
-
1 × $4,089.00
-
1 × $1,990.00
-
1 × $2,314.00
-
1 × $20,816.00
-
2 × $628.00
-
1 × $1,098.00
-
1 × $7,094.00
-
1 × $1,293.00
-
1 × $3,778.00
-
1 × $1,862.00
-
1 × $1,247.00
-
1 × $2,107.00
-
1 × $8,216.00
-
1 × $569.00
-
1 × $4,007.00
-
1 × $2,736.00
-
1 × $816.00
-
1 × $2,810.00
-
1 × $654.00
-
1 × $20,652.00
-
1 × $396.00
-
1 × $6,930.00
-
1 × $969.00
-
1 × $1,169.00
-
1 × $1,711.00
-
1 × $437.00
-
1 × $820.00
-
1 × $1,643.00
-
1 × $1,687.00
Erler zimmer 12 lead arrhythmia simulator (zoll)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty