1 × $12,461.00
-
1 × $530.00
-
1 × $2,133.00
-
1 × $399.00
-
1 × $492.00
-
1 × $1,038.00
-
1 × $5,291.00
-
1 × $606.00
-
1 × $1,516.00
-
1 × $428.00
-
1 × $897.00
-
1 × $7,433.00
-
1 × $1,902.00
-
1 × $4,063.00
-
1 × $3,283.00
-
1 × $657.00
-
1 × $1,891.00
-
1 × $819.00
-
1 × $418.00
-
1 × $468.00
-
1 × $1,255.00
-
1 × $1,171.00
-
1 × $2,834.00
-
2 × $877.00
-
1 × $3,834.00
-
1 × $2,009.00
-
1 × $1,113.00
-
1 × $575.00
-
1 × $1,091.00
-
1 × $2,164.00
-
1 × $8,707.00
-
1 × $555.00
-
1 × $15,396.00
-
1 × $24,377.00
-
1 × $13,993.00
-
1 × $852.00
-
1 × $17,804.00
-
1 × $8,542.00
-
1 × $1,752.00
-
1 × $8,381.00
-
1 × $1,428.00
-
1 × $885.00
-
1 × $476.00
-
1 × $3,982.00
-
1 × $3,419.00
-
1 × $3,806.00
-
1 × $488.00
-
1 × $2,776.00
-
1 × $494.00
-
1 × $1,711.00
-
1 × $4,007.00
-
1 × $546.00
-
1 × $809.00
-
1 × $403.00
-
1 × $12,396.00
-
2 × $399.00
-
1 × $1,653.00
-
1 × $1,014.00
-
1 × $897.00
-
1 × $1,462.00
-
1 × $896.00
-
1 × $1,646.00
-
1 × $855.00
-
1 × $2,361.00
Erler zimmer 12 lead arrhythmia simulator (zoll)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty