-
1 × $2,402.00
-
2 × $25,527.00
-
1 × $1,418.00
-
1 × $897.00
-
2 × $2,218.00
-
3 × $437.00
-
1 × $494.00
-
1 × $1,746.00
-
1 × $2,190.00
-
1 × $492.00
-
1 × $469.00
-
1 × $1,322.00
-
1 × $554.00
-
1 × $706.00
-
1 × $520.00
-
1 × $435.00
-
2 × $2,776.00
-
1 × $6,759.00
-
1 × $1,970.00
-
2 × $2,361.00
-
1 × $942.00
-
1 × $951.00
-
1 × $2,152.00
-
2 × $613.00
-
1 × $1,194.00
-
1 × $521.00
-
1 × $887.00
-
1 × $479.00
-
1 × $1,393.00
-
3 × $2,079.00
-
1 × $1,394.00
-
1 × $628.00
-
2 × $2,724.00
-
1 × $1,010.00
-
1 × $2,361.00
-
1 × $1,309.00
-
1 × $1,643.00
-
1 × $1,725.00
-
1 × $839.00
-
1 × $2,219.00
-
1 × $1,092.00
-
1 × $524.00
-
1 × $1,337.00
-
1 × $1,793.00
-
1 × $1,640.00
-
1 × $454.00
-
1 × $538.00
-
1 × $7,433.00
-
1 × $2,163.00
-
1 × $470.00
-
1 × $709.00
-
1 × $1,281.00
-
1 × $471.00
-
1 × $1,421.00
-
1 × $1,068.00
-
1 × $855.00
-
2 × $788.00
-
1 × $1,018.00
Erler Zimmer 12-lead Arrhythmia Simulator with Manikin Overlay (Large Size Skin, Marquette)
$2,361.00
Erler zimmer 12-lead arrhythmia simulator with manikin overlay (large size skin, marquette)
Features and Benefits
- Use on any large-sized manikin or simulator to change it into a 12-lead trainer.
- Pace and defibrillate directly on the overlay system connected to the interactive 12-lead ECG simulator, included with the overlay.
- You may purchase optional defibrillation training cables that allow you to have hand-free defibrillation simulation, with up to 360 joules, as well as electrical capture with your external pacer.
- The simulator capture key is used to select one of four preset pacing capture levels: 70, 80, 90 or 100mA.
- When the pacer current is greater than the selected capture level, paced beats will appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semiautomatic, or automatic defibrillator.
- Waveforms for defibrillator training include: V. Fib, V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, zPSVT, Sinus Tach, Sinus rhythm, Sinus rhythm with PVCs, and Asystole.
- Generate ST segment and T wave of abnormalities, including: Anterior MI, Inferior MI, Antero-Septal ST elevation, Anterior ST depression, Lateral ST elevation, and Inferior ST elevation. LEDs indicate: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty