-
2 × $1,753.00
-
1 × $1,098.00
-
1 × $4,461.00
-
1 × $652.00
-
1 × $3,778.00
-
1 × $1,022.00
-
1 × $2,813.00
-
1 × $3,174.00
-
1 × $1,368.00
-
1 × $5,683.00
-
1 × $554.00
-
1 × $1,290.00
-
1 × $2,361.00
-
1 × $2,361.00
-
1 × $1,467.00
-
1 × $412.00
-
1 × $396.00
-
1 × $11,331.00
-
1 × $27,142.00
-
1 × $504.00
-
1 × $444.00
-
1 × $3,486.00
-
1 × $20,652.00
-
1 × $3,181.00
-
1 × $535.00
-
1 × $403.00
-
1 × $841.00
-
1 × $623.00
-
1 × $3,008.00
-
1 × $1,052.00
-
1 × $1,414.00
-
2 × $2,009.00
-
1 × $1,281.00
-
1 × $476.00
-
1 × $4,601.00
-
1 × $1,266.00
-
1 × $1,242.00
-
1 × $665.00
-
1 × $600.00
-
1 × $5,008.00
-
1 × $1,179.00
-
1 × $1,025.00
-
1 × $12,807.00
-
1 × $533.00
-
1 × $1,147.00
-
1 × $418.00
-
1 × $3,647.00
-
1 × $1,458.00
-
1 × $1,108.00
-
1 × $5,148.00
-
1 × $2,533.00
-
1 × $1,170.00
-
1 × $3,417.00
-
1 × $1,038.00
-
1 × $437.00
-
1 × $3,411.00
-
1 × $492.00
-
1 × $490.00
-
1 × $11,378.00
-
1 × $1,389.00
-
1 × $2,223.00
-
1 × $826.00
-
1 × $616.00
-
1 × $1,202.00
Erler zimmer 12-lead arrhythmia simulator (philips)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty








