-
1 × $1,311.00
-
1 × $1,068.00
-
2 × $395.00
-
1 × $1,752.00
-
1 × $1,091.00
-
1 × $713.00
-
1 × $554.00
-
1 × $685.00
-
1 × $1,791.00
-
1 × $957.00
-
1 × $849.00
-
1 × $416.00
-
1 × $3,486.00
-
1 × $437.00
-
1 × $1,619.00
-
2 × $25,527.00
-
1 × $2,790.00
-
1 × $3,662.00
-
1 × $423.00
-
1 × $2,736.00
-
1 × $577.00
-
1 × $4,461.00
-
1 × $6,762.00
-
1 × $573.00
-
1 × $881.00
-
1 × $2,520.00
-
1 × $13,692.00
-
1 × $435.00
-
1 × $1,380.00
-
1 × $5,458.00
-
1 × $399.00
-
1 × $412.00
-
1 × $579.00
-
1 × $1,487.00
-
1 × $793.00
-
1 × $955.00
-
1 × $1,793.00
-
1 × $454.00
-
1 × $819.00
-
1 × $1,791.00
-
1 × $875.00
-
1 × $16,431.00
-
1 × $1,070.00
-
1 × $1,844.00
-
1 × $4,968.00
-
1 × $444.00
-
1 × $406.00
-
1 × $2,212.00
-
1 × $682.00
-
1 × $682.00
-
1 × $678.00
-
1 × $3,544.00
-
1 × $2,588.00
-
1 × $1,516.00
-
1 × $1,482.00
-
1 × $1,113.00
-
1 × $5,820.00
-
1 × $740.00
-
1 × $1,360.00
-
1 × $760.00
-
1 × $1,204.00
-
1 × $1,440.00
-
1 × $4,128.00
-
1 × $1,031.00
-
1 × $24,377.00
-
1 × $1,593.00
-
1 × $1,753.00
-
1 × $2,957.00
-
1 × $398.00
-
1 × $3,011.00
-
1 × $841.00
-
1 × $670.00
-
1 × $530.00
-
1 × $521.00
-
1 × $1,511.00
Erler zimmer 12-lead arrhythmia simulator (philips)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty