-
1 × $1,921.00
-
2 × $588.00
-
1 × $2,184.00
-
2 × $1,752.00
-
2 × $1,106.00
-
1 × $682.00
-
1 × $401.00
-
1 × $9,250.00
-
1 × $616.00
-
1 × $709.00
-
1 × $3,180.00
-
1 × $24,377.00
-
1 × $3,835.00
-
1 × $472.00
-
1 × $607.00
-
2 × $1,345.00
-
1 × $576.00
-
1 × $682.00
-
1 × $897.00
-
1 × $5,820.00
-
1 × $1,967.07
-
1 × $4,065.00
-
1 × $2,265.00
-
1 × $819.00
-
1 × $385.00
-
1 × $897.00
-
1 × $1,068.00
-
1 × $670.00
-
1 × $4,355.00
-
1 × $1,202.00
-
1 × $8,704.00
-
1 × $1,548.00
-
1 × $583.00
-
1 × $896.00
-
1 × $4,050.00
-
1 × $2,469.00
-
1 × $3,411.00
-
1 × $1,625.00
-
2 × $2,813.00
-
1 × $2,361.00
-
1 × $1,311.00
-
1 × $1,164.00
-
1 × $1,718.00
-
1 × $388.00
-
1 × $1,640.00
-
1 × $2,164.00
-
1 × $951.00
-
1 × $1,191.00
-
1 × $373.00
-
1 × $393.00
-
1 × $1,091.00
-
1 × $3,917.00
-
1 × $1,218.00
-
1 × $740.00
-
1 × $471.00
-
1 × $583.00
-
1 × $1,068.00
-
1 × $454.00
Erler Zimmer 12-lead Arrhythmia Simulator (Heart Start/Philips With Late VF Waveform)
$1,511.00
Erler zimmer 12-lead arrhythmia simulator (heart start/philips with late vf waveform)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty