1 × $2,724.00
-
3 × $2,790.00
-
1 × $1,337.00
-
1 × $1,562.00
-
1 × $793.00
-
1 × $457.00
-
1 × $1,511.00
-
2 × $1,970.00
-
1 × $524.00
-
1 × $399.00
-
1 × $444.00
-
1 × $4,073.00
-
1 × $547.00
-
1 × $442.00
-
1 × $1,125.00
-
1 × $1,887.00
-
1 × $1,038.00
-
1 × $760.00
-
1 × $1,206.00
-
1 × $3,704.00
-
1 × $877.00
-
2 × $573.00
-
1 × $2,435.00
-
1 × $682.00
-
2 × $1,377.00
-
1 × $582.00
-
1 × $4,091.00
-
1 × $1,626.00
-
1 × $5,820.00
-
1 × $3,917.00
-
1 × $855.00
-
1 × $2,343.00
-
1 × $968.00
-
1 × $432.00
-
2 × $6,360.00
-
1 × $954.00
-
1 × $1,844.00
-
2 × $1,643.00
-
1 × $2,476.00
-
1 × $7,433.00
-
1 × $470.00
-
1 × $416.00
-
1 × $581.00
-
1 × $520.00
-
1 × $3,835.00
-
1 × $422.00
-
1 × $484.00
-
1 × $1,642.00
-
1 × $1,092.00
-
1 × $2,465.00
-
1 × $2,184.00
-
1 × $403.00
-
1 × $2,361.00
Erler Zimmer 12-lead Arrhythmia Simulator (Heart Start/Philips With Late VF Waveform)
$1,511.00
Erler zimmer 12-lead arrhythmia simulator (heart start/philips with late vf waveform)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty