1 × $3,704.00
-
1 × $403.00
-
2 × $1,068.00
-
1 × $524.00
-
1 × $1,640.00
-
2 × $2,361.00
-
2 × $2,219.00
-
2 × $2,218.00
-
1 × $1,111.00
-
1 × $745.00
-
1 × $1,462.00
-
3 × $1,038.00
-
1 × $942.00
-
1 × $533.00
-
1 × $388.00
-
4 × $613.00
-
1 × $3,244.00
-
1 × $396.00
-
1 × $628.00
-
1 × $569.00
-
1 × $492.00
-
1 × $554.00
-
1 × $468.00
-
1 × $403.00
-
1 × $1,198.00
-
1 × $1,041.00
-
1 × $1,511.00
-
1 × $8,704.00
-
1 × $637.00
-
1 × $1,202.00
-
3 × $1,091.00
-
3 × $1,018.00
-
1 × $2,361.00
-
1 × $855.00
-
2 × $25,527.00
-
1 × $521.00
-
1 × $457.00
-
1 × $3,237.00
-
1 × $1,125.00
-
1 × $2,009.00
-
1 × $698.00
-
1 × $454.00
-
2 × $607.00
-
1 × $5,086.00
-
1 × $2,847.00
-
1 × $7,433.00
-
1 × $616.00
-
2 × $3,492.00
-
1 × $525.00
-
1 × $520.00
-
1 × $1,511.00
-
1 × $2,390.00
-
1 × $1,345.00
-
1 × $1,421.00
-
1 × $1,337.00
-
3 × $537.00
-
1 × $397.00
-
1 × $760.00
-
2 × $385.00
-
1 × $466.00
-
1 × $1,311.00
-
1 × $2,361.00
-
1 × $576.00
-
1 × $530.00
-
1 × $1,718.00
-
1 × $1,256.00
-
1 × $471.00
-
1 × $492.00
-
1 × $1,887.00
-
1 × $1,593.00
-
1 × $444.00
-
1 × $608.00
-
1 × $3,778.00
-
1 × $2,900.00
-
1 × $446.00
-
1 × $2,452.00
-
1 × $1,389.00
-
1 × $1,725.00
-
1 × $1,034.00
-
1 × $632.00
-
1 × $3,311.00
-
2 × $1,516.00
-
1 × $1,687.00
-
1 × $2,492.00
-
1 × $1,418.00
-
1 × $5,820.00
-
1 × $393.00
-
1 × $471.00
-
1 × $2,620.00
-
1 × $1,369.00
-
1 × $818.00
-
1 × $1,005.00
-
1 × $427.00
-
1 × $803.00
-
1 × $2,782.00
-
1 × $522.00
-
1 × $6,360.00
-
1 × $7,751.00
-
1 × $3,411.00
Erler Zimmer 12-lead Arrhythmia Simulator (Heart Start/Philips With Late VF Waveform)
$1,511.00
Erler zimmer 12-lead arrhythmia simulator (heart start/philips with late vf waveform)
Features and Benefits
- Pace and defibrillate directly into this interactive 12-lead ECG simulator through your hands-free defibrillation cable.
- Connects directly to monitor, does not work with manikin
- Simulate electrical capture with your external pacer.
- Press simulator capture key to select one of four preset pacing capture levels: 70, 80, 90, or 100mA.
- When pacer current is greater than selected capture level, paced beats appear on your monitor.
- Waveforms for pacing include: Sinus Brady (two), 1st degree A-V block, 2nd degree type I A-V block, 2nd degree type II A-V block, 2nd degree type II A-V block with PVCs, and 3rd degree A-V block.
- Simulate cardioversion with your manual, semi-automatic, or automatic defibrillator.
- Activate convert feature to select before defib discharge another rhythm to run immediately after defib discharge.
- Waveforms for defibrillator training include: V. Fib., V. Tach (high rate), V. Tach (low rate), Torsade, A. Fib, A. Flutter, PSVT, Sinus Tach, Sinus Rhythm, Sinus Rhythm with PVCs, Asystole, and NSR.
- Generate realistic 12-lead ECG rhythms.
- Connect your ECG cable to simulator’s 10 ECG snaps.
- Independent chest lead and limb lead ECG signals create realistic 12-lead ECGs for each rhythm.
- Generate ST segment and T wave abnormalities including: Anterior MI, Inferior MI, Antero-Septal ST Elevation, Anterior ST Depression, Lateral ST Elevation, and Inferior ST Elevation.
- LED indicators: pacer pulse detection, defib discharge detection, and low battery.
Warranty Information
- 1-Year Warranty